Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Water Health ; 22(3): 601-611, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38557574

RESUMO

Coronavirus disease 2019 (COVID-19) is an infectious viral disease caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) that emerged at the end of 2019. SARS-CoV-2 can be transmitted through droplets, aerosols, and fomites. Disinfectants such as alcohol, quaternary ammonium salts, and chlorine-releasing agents, including hypochlorous acid, are used to prevent the spread of SARS-CoV-2 infection. In the present study, we investigated the efficacy of ionless hypochlorous acid water (HOCl) in suspension and by spraying to inactivate SARS-CoV-2. The virucidal efficacy of HOCl solution in tests against SARS-CoV-2 was evaluated as 50% tissue culture infectious dose. Although the presence of organic compounds influenced the virucidal efficacy, HOCl treatment for 20 s was significantly effective to inactivate Wuhan and Delta strains in the suspension test. HOCl atomization for several hours significantly reduced the SARS-CoV-2 attached to plastic plates. These results indicate that HOCl solution with elimination containing NaCl and other ions may have high virucidal efficacy against SARS-CoV-2. This study provides important information about the virucidal efficacy and use of HOCl solution.


Assuntos
COVID-19 , Desinfetantes , Humanos , SARS-CoV-2 , COVID-19/prevenção & controle , Ácido Hipocloroso/farmacologia , Água , Desinfetantes/farmacologia
2.
J Infect Chemother ; 30(2): 123-128, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37758000

RESUMO

INTRODUCTION: In daycare centers, infants come in close contact with each other, and contact, droplet, and mouth-to-mouth infections may occur owing to sharing of toys. Additional effective disinfection methods should be considered aside from wiping with disinfectants-including alcohol or sodium hypochlorite solution-for environmental disinfection of daycare centers. We aimed to examine the usefulness of hypochlorous acid water atomization in the effective disinfection of the classroom environment and toys at a nursery school. METHODS: Environmental cultures of the nursery and toys were prepared to evaluate the species and bacterial load and to assess the contaminated areas. Staphylococcus aureus petri dishes were placed at high-frequency contact sites, and hypochlorous acid water was atomized to achieve a 0.03-ppm atmospheric chlorine concentration. After the atomization, the amount of S. aureus bacteria on the Petri dish and the changes in bacterial count isolated from the environment and toys were evaluated. RESULTS: Hypochlorous acid water atomization was performed for 5 h to avoid condensation. After a 3-h atomization, ≥99.99% of S. aureus was eliminated on petri dishes; furthermore, a significant disinfection effect was observed on environmental bacteria at least 1 h after atomization. For rubber and textile toys, the significant disinfection effect was observed 1 h after atomization, and for plastic toys, the effect was observed 3 h after atomization. CONCLUSIONS: Hypochlorous acid water atomization is a useful strategy to disinfect nursery school classrooms.


Assuntos
Desinfetantes , Ácido Hipocloroso , Lactente , Humanos , Ácido Hipocloroso/farmacologia , Escolas Maternais , Staphylococcus aureus , Água , Desinfetantes/farmacologia , Bactérias , Antibacterianos/farmacologia , Etanol/farmacologia
3.
Sensors (Basel) ; 21(24)2021 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-34960358

RESUMO

This paper presents an ultra-low power hand gesture sensor using electrostatic induction for mobile devices. Two electrodes, which consist of electret foils stacked on metal sheets, are used to recognize two gestures such as hand movements from left to right and right to left. The hand gesture recognition is realized by detecting the electrostatic induction currents induced by hand movements. However, the electrostatic induction currents are significantly small; hence, a hand gesture recognition chip is first designed in this study to amplify and detect the small electrostatic induction currents with low power. This chip is fabricated in a commercial 180 nm complementary metal oxide semiconductor (CMOS) process, and the measurement results indicate that the fabricated gesture recognition chip consumes 406 nW, which is less than 1/100th of the power dissipation of conventional gesture sensors.


Assuntos
Gestos , Extremidade Superior , Algoritmos , Eletrodos , Mãos , Reconhecimento Psicológico , Eletricidade Estática
4.
Adv Mater ; 28(17): 3298-304, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26922899

RESUMO

Large-bandwidth, low-operation-voltage, and uniform organic amplifiers are fabricated on ultrathin foils. By the integration of short-channel OTFTs and AlOx capacitors, organic amplifiers with a bandwidth of 25 kHz are realized, demonstrating the highest gain-bandwidth product (GBWP) reported to date. Owing to material and process advancements, closed-loop architectures operate at frequencies of several kilohertz with an area smaller than 30 mm(2) .

5.
IEEE Trans Biomed Circuits Syst ; 8(6): 824-33, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24951707

RESUMO

A 64-channel surface electromyogram (EMG) measurement sheet (SEMS) with 2 V organic transistors on a 1 µm-thick ultra-flexible polyethylene naphthalate (PEN) film is developed for prosthetic hand control. The surface EMG electrodes must satisfy the following three requirements; high mechanical flexibility, high electrode density and high signal integrity. To achieve high electrode density and high signal integrity, a distributed and shared amplifier (DSA) architecture is proposed, which enables an in-situ amplification of the myoelectric signal with a fourfold increase in EMG electrode density. In addition, a post-fabrication select-and-connect (SAC) method is proposed to cope with the large mismatch of organic transistors. The proposed SAC method reduces the area and the power overhead by 96% and 98.2%, respectively, compared with the use of conventional parallel transistors to reduce the transistor mismatch by a factor of 10.


Assuntos
Membros Artificiais , Eletromiografia , Mãos , Transistores Eletrônicos , Eletrodos , Eletromiografia/instrumentação , Eletromiografia/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...